Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Use of CAD/CAM Cobalt-Chromium Framework to Optimize Subgingival Prosthetic Contours and Improve Esthetics: Anterior Mandibular Case Reports
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 38 , Issue 0
Supplement 2018

Pages s79–s85


The Use of CAD/CAM Cobalt-Chromium Framework to Optimize Subgingival Prosthetic Contours and Improve Esthetics: Anterior Mandibular Case Reports

Gaetano Calesini, MD, DDS, CDT/Federica Papacchini, DDS, MSc, PhD/Agostino Scipioni, MD, DDS, CDT


PMID: 29253041
DOI: 10.11607/prd.2813

Although implant therapy in esthetically relevant areas is currently based on a prosthetically driven philosophy, anatomical and technical factors may impair ideal implant placement. In these scenarios, the clinician is frequently asked to solve the discrepancy between the implant emergence and the ideal coronal anatomy of the final restoration. This report describes how changes of the implant abutment–crown contour in specific locations may be intentionally promoted to determine improvements of the peri-implant soft tissues and overall esthetic integration. Cobalt-chromium alloys together with computer-aided design/computer-assisted manufacture technologies are critical factors in achieving this goal. Case reports for the mandibular anterior dentition demonstrated the ability to enhance biologic and esthetic results of malpositioned implants.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help